    Acute thrombus formation on phosphorilcholine surface modified flow diverters

    Get PDF
    PURPOSE: Thromboembolic complications remain a limitation of flow diverting stents. We hypothesize that phosphorilcholine surface modified flow diverters (Pipeline Flex with Shield Technology, sPED) would have less acute thrombus formation on the device surface compared with the classic Pipeline Embolization device (cPED). METHODS: Elastase-induced aneurysms were created in 40 rabbits and randomly assigned to receive cPED or sPED devices with and without dual antiplatelet therapy (DAPT) (four groups, n=10/group). Angioplasty was performed to enhance apposition and create intimal injury for a pro-thrombotic environment. Both before and after angioplasty, the flow diverter was imaged with intravascular optical coherence tomography. The outcome measure was the number of predefined segments along the implant relative to the location of the aneurysm with a minimum of 0 (no clot formation) and maximum of 3 (all segments with thrombus). Clot formation over the device at ostia of branch arteries was assessed as either present or absent. RESULTS: Following angioplasty, the number of flow diverter segments with clots was significantly associated with the flow diverter (p \u3c 0.0001), but not with DAPT (p=0.3872) or aneurysm neck size (p=0.8555). The incidence rate for clots with cPED was 1.72 times more than with sPED. The clots on the flow diverter at the location corresponding to side branch ostia was significantly lower with sPED than with cPED (OR 0.180; 95% CI 0.044 to 0.734; p=0.0168), but was not associated with DAPT (p=0.3198). CONCLUSION: In the rabbit model, phosphorilcholine surface modified flow diverters are associated with less thrombus formation on the surface of the device

    Quantitative assessment of device-clot interaction for stent retriever thrombectomy

    Get PDF
    PURPOSE: Rapid revascularization in emergent large vessel occlusion with endovascular embolectomy has proven clinical benefit. We sought to measure device-clot interaction as a potential mechanism for efficient embolectomy. METHODS: Two different radiopaque clot models were injected to create a middle cerebral artery occlusion in a patient-specific vascular phantom. A radiopaque stent retriever was deployed within the clot by unsheathing the device or a combination of unsheathing followed by pushing the device (n=8/group). High-resolution cone beam CT was performed immediately after device deployment and repeated after 5 min. An image processing pipeline was created to quantitatively evaluate the volume of clot that integrates with the stent, termed the clot integration factor (CIF). RESULTS: The CIF was significantly different for the two deployment variations when the device engaged the hard clot (p=0.041), but not the soft clot (p=0.764). In the hard clot, CIF increased significantly between post-deployment and final imaging datasets when using the pushing technique (p=0.019), but not when using the unsheathing technique (p=0.067). When we investigated the effect of time on CIF in the different clot models disregarding the technique, the CIF was significantly increased in the final dataset relative to the post-deployment dataset in both clot models (p=0.004-0.007). CONCLUSIONS: This study demonstrates in an in vitro system the benefit of pushing the Trevo stent during device delivery in hard clot to enhance integration. Regardless of delivery technique, clot-device integration increased in both clot models by waiting 5 min

    Quantifying and Mitigating Motor Phenotypes Induced by Antisense Oligonucleotides in the Central Nervous System [preprint]

    Get PDF
    Antisense oligonucleotides (ASOs) are emerging as a promising class of therapeutics for neurological diseases. When injected directly into the cerebrospinal fluid, ASOs distribute broadly across brain regions and exert long-lasting therapeutic effects. However, many phosphorothioate (PS)-modified gapmer ASOs show transient motor phenotypes when injected into the cerebrospinal fluid, ranging from reduced motor activity to ataxia or acute seizure-like phenotypes. The effect of sugar and phosphate modifications on these phenotypes has not previously been systematically studied. Using a behavioral scoring assay customized to reflect the timing and nature of these effects, we show that both sugar and phosphate modifications influence acute motor phenotypes. Among sugar analogues, PS-DNA induces the strongest motor phenotype while 2’-substituted RNA modifications improve the tolerability of PS-ASOs. This helps explain why gapmer ASOs have been more challenging to develop clinically relative to steric blocker ASOs, which have a reduced tendency to induce these effects. Reducing the PS content of gapmer ASOs, which contain a stretch of PS-DNA, improves their toxicity profile, but in some cases also reduces their efficacy or duration of effect. Reducing PS content improved the acute tolerability of ASOs in both mice and sheep. We show that this acute toxicity is not mediated by the major nucleic acid sensing innate immune pathways. Formulating ASOs with calcium ions before injecting into the CNS further improved their tolerability, but through a mechanism at least partially distinct from the reduction of PS content. Overall, our work identifies and quantifies an understudied aspect of oligonucleotide toxicology in the CNS, explores its mechanism, and presents platform-level medicinal chemistry approaches that improve tolerability of this class of compounds

    A neurovascular high-frequency optical coherence tomography system enables in situ cerebrovascular volumetric microscopy

    Get PDF
    Intravascular imaging has emerged as a valuable tool for the treatment of coronary and peripheral artery disease; however, no solution is available for safe and reliable use in the tortuous vascular anatomy of the brain. Endovascular treatment of stroke is delivered under image guidance with insufficient resolution to adequately assess underlying arterial pathology and therapeutic devices. High-resolution imaging, enabling surgeons to visualize cerebral arteries\u27 microstructure and micron-level features of neurovascular devices, would have a profound impact in the research, diagnosis, and treatment of cerebrovascular diseases. Here, we present a neurovascular high-frequency optical coherence tomography (HF-OCT) system, including an imaging console and an endoscopic probe designed to rapidly acquire volumetric microscopy data at a resolution approaching 10 microns in tortuous cerebrovascular anatomies. Using a combination of in vitro, ex vivo, and in vivo models, the feasibility of HF-OCT for cerebrovascular imaging was demonstrated

    Quantitative Characterization of Recanalization and Distal Emboli with a Novel Thrombectomy Device

    No full text
    PURPOSE: The first-pass effect during mechanical thrombectomy improves clinical outcomes regardless of first-line treatment approach, but current success rates for complete clot capture with one attempt are still less than 40%. We hypothesize that the ThrombX retriever (ThrombX Medical Inc.) can better engage challenging clot models during retrieval throughout tortuous vasculature in comparison with a standard stent retriever without increasing distal emboli. MATERIALS AND METHODS: Thrombectomy testing with the new retriever as compared to the Solitaire stent retriever was simulated in a vascular replica with hard and soft clot analogs to create a challenging occlusive burden. Parameters included analysis of distal emboli generated per clot type, along with the degree of recanalization (complete, partial or none) by retrieval device verified by angiography. RESULTS: The ThrombX device exhibited significantly higher rates of first-pass efficacy (90%) during hard clot retrieval in comparison with the control device (20%) (p \u3c 0.009), while use of both techniques during soft clot retrieval resulted in equivalent recanalization. The soft clot model generated higher numbers of large emboli ( \u3e 200 mum) across both device groups (p = 0.0147), and no significant differences in numbers of distal emboli were noted between the ThrombX and Solitaire techniques. CONCLUSIONS: Irrespective of clot composition, use of the ThrombX retriever demonstrated high rates of complete recanalization at first pass in comparison with a state-of-the-art stent retriever and proved to be superior in the hard clot model. Preliminary data suggest that risk of distal embolization associated with the ThrombX system is comparable to that of the control device

    Trigeminocardiac reflex caused by selective angiography of the middle meningeal artery

    No full text
    We describe an interesting case of trigeminocardiac reflex (TCR) caused by selective angiography of the middle meningeal artery (MMA). A 28-year-old woman presented with a symptomatic meningioma. Preoperative tumour embolisation was performed. In the procedure, when selective MMA angiography was done with Omnipaque 300 mg I/mL for 3 mL by manual injection, the patient complained of flashing lights in her eye followed by vomiting and bradycardia down to 40 bpm without increased intracranial pressure signs. On selective MMA angiography, the choroidal crescent and arteries of the periorbital region were opacified by anastomosis from the MMA via the meningo-ophthalmic artery. We diagnosed that her symptoms were caused by selective MMA angiography leading to high pressure stimulation towards the ophthalmic nerve innervation around the orbit as a TCR. We suggest that the operator should be prepared to manage TCR during treatment with expected selective MMA angiography, and gentle low pressure contrast injection should be attempted

    Novel Distal Emboli Protection Technology: The EmboTrap

    No full text
    Background: Over the course of the thrombectomy procedure, clot fragments may become dislodged and lead to downstream emboli due to manipulation of an endovascular device. The EmboTrap thrombectomy system features an inner stent channel with an outer stent trap design that may potentially reduce the risk of distal clot fragmentation during clot removal. We tested the hypothesis that distal emboli to both the same and new territory generated during mechanical thrombectomy are a function of device design. Methods: EmboTrap and Solitaire thrombectomy were conducted in an in vitro model system that mimicked a middle-cerebral artery (MCA) occlusion within a complete circle of Willis vascular replica and a contrast-enhanced clot analog. Emboli generated during the procedure with a size \u3e 1,000 mum were collected and measured with calipers. The Coulter principle was used to characterize emboli with a size between 200 and 1,000 microm. Results: EmboTrap thrombectomy resulted in a significant reduction in the risk of large emboli ( \u3e 1,000 mum) formation as compared to first-generation stent retriever thrombectomy (p = 0.031, Fisher exact test). The majority of emboli \u3e 1,000 mum ( approximately 80%) were found in the MCA, regardless of device type. There was no significant difference between the EmboTrap and Solitaire in 200 to 1,000 mum emboli formation (p = 0.89, Mann-Whitney test). When combining all emboli in the most dangerous range ( \u3e 200 mum), EmboTrap offered a size reduction of emboli (p = 0.022). Conclusion: The risk of distal embolization can be altered with improved stent retriever design. When encountering fragment-prone clots, EmboTrap thrombectomy may lower the risk of distal embolization

    Microcatheter navigation through the clot: does size matter

    No full text
    BACKGROUND: Despite high recanalization rates achieved with endovascular treatment of acute ischemic strokes, around 50% of eligible patients will not achieve a good outcome. Parameters that may determine patient outcomes include: time from puncture to recanalization, the collateral status, the anesthesia regimen, blood pressure management, and distal emboli. Characterization of distal emboli generated during mechanical thrombectomy has been performed in previous studies. OBJECTIVE: To further investigate the risk of distal embolization associated with microcatheter navigation across the clot. METHODS: A contrast-enhanced clot analog was used in an in vitro model that mimicked a middle cerebral artery occlusion within a complete circle of Willis vascular replica. The clot was crossed with one of the following microcatheters: Pro18, XT-27 or 3MAX. The emboli generated during the procedure were collected and measured. RESULTS: The use of Pro18 and XT-27 resulted in a significant reduction of visible particles (size \u3e /=500 microm) as compared with the 3MAX catheter (P \u3c 0.003). For the size range between 8 and 200 microm, there was a trend for Pro18 to generate fewer particles (-18%) than XT-27 but without statistical significance (P \u3e 0.05). In comparison with previously published data, acquired under the same conditions, it was found that the clot crossing maneuver accounts approximately for 12% of the total number of small emboli ( \u3c 200 microm) induced during a stent retriever-mediated mechanical thrombectomy procedure via a balloon guide catheter. CONCLUSIONS: The clot crossing maneuver has a significant effect on the total number of small particles induced during mechanical thrombectomy. Smaller microcatheter sizes should be favored when possible

    Intravascular Optical Coherence Tomography for Neurointerventional Surgery

    No full text
    Optical coherence tomography (OCT) is a high-resolution imaging modality that uses backscattered light to produce cross-sectional images of biological tissue with micrometer resolution. The first publication using the term OCT appeared in 1991 and arose as a collaboration between the Massachusetts Institute of Technology (MIT) and Harvard University. The high-spatial resolution makes it an optimal modality for imaging pathologies which affect individual tissue layers and evaluating microfeatures of therapeutic devices. The first in vivo application of OCT was the imaging of the anterior segment of the human eye, an ideal target for this technology since the transparency of the ocular media allows for noninvasive imaging of important eye structures, such as the cornea and the retina. A few years later, the integration of fiber optic technologies into OCT systems enabled the development of intravascular imaging catheters for the in vivo visualization of coronary arteries and in situ stents in high resolution

    High frequency optical coherence tomography assessment of homogenous neck coverage by intrasaccular devices predicts successful aneurysm occlusion

    No full text
    BACKGROUND: High frequency optical coherence tomography (HF-OCT) is a novel intravascular imaging technology developed for use in the cerebral vasculature. We hypothesize that HF-OCT characterization of intrasaccular device neck coverage can prognosticate exclusion of the aneurysm from the circulation. METHODS: Bifurcation and sidewall aneurysms were made in six dogs. Seven aneurysms were treated with next generation intrasaccular devices (NGID) and four with traditional platinum coils. HF-OCT was performed to interrogate gaps in the neck coverage, coil herniation, or acute thrombus formation. Animals were re-imaged at 7, 30, 90, and 180 days following aneurysm embolization. An automated image processing method segmented the devices at the neck of the aneurysm and quantified neck coverage. The largest coverage gap was used to predict aneurysm occlusion at 180 days. RESULTS: No difference was found in occlusion rates between the coil and NGID groups (P=0.45). Successful segmentation of the NGID construct was achieved in all cases. A coverage gap \u3e 1 mm(2) was found to predict failed aneurysm occlusion (P=0.047). This threshold was able to predict all cases of failed occlusion. The average number of devices needed to treat the aneurysm was lower in the NGID group (1.9 vs 6.75, P=0.009). HF-OCT showed strong agreement with scanning electron microscopy (bias 0.0024 mm(2) (95% CI -0.0279, 0.0327)). CONCLUSIONS: HF-OCT enables precise and accurate measurement of coverage gaps at the neck of aneurysms treated with intrasaccular devices in vivo. We provide in vivo evidence that uniform aneurysm neck coverage by intrasaccular devices is critical for aneurysm occlusion. permissions